TransEnd by Joslyn |
|
|
|
Data Sheets
TransEnd 25 Data Sheet (98KB)
TransEnd 50 Data Sheet (97KB)
TransEnd 80 Data Sheet (97KB)
TransEnd 100 Data Sheet (96KB) |
TransEnd™ surge protectors combine practicality with many special features to deliver more performance than any other device in its class. Designed to meet demanding project requirements, TransEnd is the right choice for today’s competitive environment. These MOV-based protectors are available in all standard low-voltage AC configurations with surge current capacities ranging from 25 kA to 100 kA.
Sensitive electrical and electronic equipment requires clean power and protection against lightning damage and surge-induced degradation. TransEnd delivers just that. These MOV-based protectors are available in all standard low-voltage AC configurations with surge current capacities ranging from 25 kA to 100 kA. From manufacturing plants, commercial buildings and military installations to hospitals, data centers, and telecommunications operations, TransEnd cost-effectively satisfies the protection requirements of all types of facilities.
Immediate shipment! Featuring 25kA, 50kA, 80kA and 100kA models
· Protects facilities and equipment against catastrophic lightning strikes and internally generated electrical transients
· Tested single-pulse surge current capacity per NEMA 2.2.9 and 3.9 recommendations
· Comes with pre-wired pigtail terminals to streamline installation
· Features arc-quenching, sand-packed design
· Backed by certified, independent laboratory performance test reports
· 3-day or less delivery
Proven technology: TransEnd delivers worry-free performance in a reliable, innovative design. The tested single-pulse surge current capacity (per mode) is tested per NEMA recommendations. Sand-packed MOV arrays equally share current to suppress transients before they reach sensitive loads while capacitors filter out high-frequency noise and low-level transients. TransEnd is designed and tested to withstand surge currents in accordance with ANSI/IEEE recommendations.
Instantaneous protection: TransEnd responds immediately and reliably to repeated high-current lightning incidents and other transient voltage surges. All TransEnd models are designed to exceed the minimum performance criteria of Bellcore and withstand larger impulses referenced in IEEE.
Superior internal construction: TransEnd’s innovative design ensures dependable operation. The suppression filter components are bolted directly to copper bus bars, lowering system impedance and clamping voltage and increasing reliability.
Status indicators: LEDs for each phase illuminate to clearly indicate protection is active.
Prewired: For ease of installation, TransEnd is equipped with 24-inch, stranded #10 AWG pigtail conductors. The conductors can be cut to fit the application and to permit the shortest connection for optimum performance.
Flex Conduit: For easy field installation, TransEnd is factory-equipped with a flexible conduit and a versatile ¾-inch-diameter fitting, allowing the installer to use either flex or conduit.
Rugged, Compact Enclosure: Measuring only 7"W x 7"H x 5"D, TransEnd easily installs in tight spaces. The NEMA 4 fiberglass-reinforced plastic (FRP) housing features a nonremovable cover for protection against tampering.
Warranty: Five-Year Product Warranty
New from the pioneer in AC surge protection, the Joslyn® TransEnd™ has everything you look for in a small, powerful surge protection device.
Versatility. Reliability. Value.
TransEnd combines practicality with many special features to deliver more performance than any other device in its class. Designed to meet demanding project requirements, TransEnd is the right choice for today's competitive environment.
Sensitive electrical and electronic equipment requires clean power and protection against lightning damage and surge-induced degradation. TransEnd delivers just that. These MOV-based protectors are available in all standard low-voltage AC configurations with surge current capacities ranging from 25 kA to 100 kA. From manufacturing plants, commercial buildings and military installations to hospitals, data centers, and telecommunications operations, TransEnd cost-effectively satisfies the protection requirements of all types of facilities.
Put Joslyn technical expertise to work for you
You can look to our Applications Engineering staff for help in choosing the TransEnd units for your specific applications and requirements. To assist you in total power systems engineering, Joslyn maintains professional alliances with major switchgear, power cabinet and electronic equipment manufacturers, as well as electrical and grounding advisory firms. We will coordinate integration of equipment offerings and engineering services to ensure value-based solutions consistent with sound engineering practices.
Communications system and point-of-use protection
Voice/data communications lines are highly susceptible to lightning and transients that cause errors or loss of transmitted data. Our communications protection devices maximize the uptime and reliability of telephone, fax, modem and dial-up lines; communications servers; and satellite communications, cable television and networked systems. Point-of-use protection for AC power applications is the job our hard-wired, series-connected LoadGuard™ unit handles with ease. For more details, refer to page X.
"24x7" installation hotline
TransEnd users have access to a dedicated, toll-free "24x7" hotline. You can access our professional field service engineers by dialing:
888-200-6400 Nights, weekends and holidays
800-238-5000 Monday through Friday, 8:00 a.m. - 5:00 p.m. (CST)
TransEnd: Easy to specify. Easy to install.
Tested Single-Pulse Surge Current Capacity (per mode):
TransEnd 100: 100kA
TransEnd 80: 80kA
TransEnd 50: 50kA
TransEnd 25: 25Ka |
|
Responsive Customer Service
To place orders or inquire about product pricing, availability or order status, please contact Joslyn Customer Service. Our professional staff of representatives is available to assist you from 6:00 a.m. to 5:00 p.m. (Pacific), Monday through Friday. When you require technical support, your call will be directed immediately to our Applications Engineering team.
Frequency
|
Model XN25-100 (L-N) |
Model XN25-100 (L-N) |
6-in. Hook-Up Wire
50-ft. Noise Source |
6-in. Hook-Up Wire
100-ft. Noise Source |
db |
db |
100kHz |
-50 |
-50 |
1MHz |
-34 |
-39 |
10MHz |
-34 |
-40 |
100MHz |
-47 |
-53 |
|
standard |
description |
UL 1449 |
Underwriters Laboratories standard that establishes requirements for surge suppression safety and performance. Commonly recognized as a benchmark test for product comparison |
UL 1283 |
Underwriters Laboratories standard dictating requirements for electromagnetic interference (EMI) filters installed on, or connected to, 600V or lower potential circuits installed in accordance with the National Electrical Code. Also covers filters used to attenuate unwanted high frequency signals generated from electromagnetic sources |
CUL |
Canadian version of Underwriters Laboratories |
NEMA LS-1 |
The specification format guideline published by the National Electrical Manufacturers Association for specifiers and customers investigating Low Voltage Surge Protection Devices |
|
6kV / 500A combination waveform |
system voltage
|
MODEL NO.
|
PROTECTION MODES |
L-N
|
L-G
|
N-G
|
L-L
|
120/208
|
XN100-120/208-3GY |
391 |
391 |
388 |
735 |
XN80-120/208-3GY |
391 |
391 |
388 |
735 |
XN50-120/208-3GY |
391 |
391 |
388 |
735 |
XN25-120/208-3GY |
408 |
397 |
392 |
784 |
277/480
|
XN100-277/480-3GY |
890 |
868 |
820 |
1665 |
XN50-277/480-3GY |
890 |
868 |
820 |
1665 |
XN80-277/480-3GY |
890 |
868 |
820 |
1665 |
XN25-277/480-3GY |
890 |
868 |
820 |
1665 |
Modes of Protection: L-N, L-G, N-G, L-L EMI/RFI
Noise Rejection: Filtering Attenuation Frequencies
Method of Operation
When a transient surge exceeds the normal system voltage, TransEnd responds within nanoseconds and changes state from a high-impedance open circuit to a low-impedance shunt (short circuit). Connected in parallel with the facility’s loads, TransEnd diverts damaging current away from sensitive loads while simultaneously reducing (clamping) the high transient voltage to harmless levels. Upon the end of the transient event, TransEnd automatically returns to its normal operating condition without service interruption.
Applicable approvals and standards
UL 1449, 2nd Edition: Underwriters Laboratories standard that establishes requirements for surge suppression safety.
CUL: Canada Underwriters Laboratories standard that establishes requirements for surge suppression safety.
UL 1283: Underwriters Laboratories standard specifying requirements for electromagnetic interference (EMI) filters permanently installed in systems of 600V or less. The requirements also cover filters used to attenuate unwanted radio frequency interference (RFI) generated by electromagnetic sources.
NEMA LS-1: The specification format guideline published by the National Electrical Manufacturers Association for specifiers and customers investigating Low-Voltage Surge Protection Devices.
ANSI/IEEE C62.41: IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits
ANSI/IEEE C62.45: IEEE Guide on Surge Testing for Equipment Connected to Low-Voltage AC Power Circuits.
ANSI/IEEE C62.1: IEEE Standard for Gapped Silicon-Carbide Surge Arresters for AC Power Circuits
ANSI/IEEE C62.11: IEEE Standard for Metal-Oxide Surge Arresters for Alternating Current Power Circuits
Critical considerations when selecting surge protection devices
Two primary factors influence the minimum life expectancy of a surge protection device: the frequency and the intensity of surge-causing events (for example, lightning- induced surges, power factor correction capacitor and load switching). For optimum protection, it is imperative to properly select the device appropriate for the following factors:
- the facility’s exposure to surges (rather than to the size of the load or service);
- the criticality or value of the equipment being protected;
- the location of the surge protection device within the facility’s power distribution system; and
- the level of power disturbances generated by the facility’s electrical and electronic equipment.
Based on your project and protection requirements, we can help you determine which devices and installation locations will best achieve your objectives.
Standard Model Numbers
TransEnd 25
XN25-120/240-2G, XN25-120/208-3GY, XN25-220/380-3GY, XN25-277/480-3GY, XN25-347/600-3GY, XN25-120/240-3GHD, XN25-240-3DG, XN25-380-3DG, XN25-480-3DG,XN25-600-3DG
TransEnd 50
XN50-120/240-2G, XN50-120/208-3GY, XN50-220/380-3GY, XN50-277/480-3GY, XN50-347/600-3GY, XN50-120/240-3GHD, XN50-240-3DG, XN50-380-3DG, XN50-480-3DG, XN50-480-3DG-FC, XN50-600-3DG
TransEnd 80
XN80-120/240-2G, XN80-120/208-3GY, XN80-220/380-3GY, XN80-277/480-3GY, XN80-347/600-3GY, XN80-120/240-3GHD, XN80-240-3DG, XN80-380-3DG, XN80-480-3DG,XN80-600-3DG
TransEnd 100
XN100-120/240-2G, XN100-120/208-3GY, XN100-220/3100-3GY, XN100-277/4100-3GY,XN100-347/600-3GY, XN100-120/240-3GHD, XN100-240-3DG, XN100-3100-3DG, XN100-4100-3DG, XN100-600-3DG
5-Year Product Warranty
Options
Dry Contacts
Single Form "C" dry contacts for remote alarm monitoring are available as an option. To order a model with dry contacts, add suffix "-FCC" to the standard part number.Example: XN100-120/208-3GY-FCC
Fittings
Option A: Metallic conduit installation kit has a ¾" x 3" metallic nipple and all associated hardware required to compelte the TransEnd installation. Part No. 300-0155-001
Option B: Flexible plastic conduit installation kit, including 18" flexible conduit and all associated hardware required to complete the TransEnd installation.
Specifications
Dimensions: 7"H x 7"W x 5"D
Weight (all models): 12.7 lbs.
Enclosure Type: NEMA 4, surface-mount
Operating Environment: -40oC to +60oC, 5% to 95% noncondensing humidity
Connection Method: Parallel
Protection Modes: L-N, L-G, N-G, L-L |
|
|
|
TRANSEND
STANDARD TRANSEND 25 MODEL NUMBERS
Model No. System Voltage, Service Configuration
XN25-120/240-2G 120/240VAC, 1 φ 3-wire SPLIT-PHASE, w/ground
XN25-120/208-3GY 120/208VAC, 3 φ 4-wire WYE, w/ground
XN25-220/380-3GY 220/380VAC, 3 φ 4-wire WYE, w/ground
XN25-277/480-3GY 277/480VAC, 3 φ 4-wire WYE, w/ground
XN25-347/600-3GY 347/600VAC, 3 φ 4-wire WYE, w/ground
XN25-120/240-3GHD 120/240VAC, 3 φ high-leg DELTA, w/ground (B phase must be 208V)
XN25-240-3DG 240VAC, 3 φ , 3-wire DELTA, w/ground
XN25-380-3DG 380VAC, 3 φ, 3-wire DELTA, w/ground
XN25-480-3DG 480VAC, 3 φ , 3-wire DELTA, w/ground
XN25-600-3DG 600VAC, 3 φ , 3-wire DELTA, w/ground
TYPICAL CLAMPING VOLTAGE DATA (6kV / 500A Combination Waveform)
System Model Protection Modes
Voltage No. L-N L-G N-G L-L
120 / 240 XN25-120/240-2G 408 397 392 784
120 / 208 XN25-120/208-3GY 408 397 392 784
220 / 380 XN25-220/380-3GY 733 752 668 1433
277 / 480 XN25-277/480-3GY 890 868 820 1665
347 / 600 XN25-347/600-3GY 1152 1185 1040 2265
120 / 240 XN25-120/240-3GHD 408x733 397x752 392 784x1433
240 XN25-240-3DG – 752 – 784
380 XN25-380-3DG – 1185 – 1433
480 XN25-480-3DG – 1451 – 1717
600 XN25-600-3DG – 1663 – 227
STANDARD TRANSEND 50 MODEL NUMBERS
Model No. System Voltage, Service Configuration
XN50-120/240-2G 120/240VAC, 1 φ 3-wire SPLIT-PHASE, w/ground
XN50-120/208-3GY 120/208VAC, 3 φ 4-wire WYE, w/ground
XN50-220/380-3GY 220/380VAC, 3 φ 4-wire WYE, w/ground
XN50-277/480-3GY 277/480VAC, 3 φ 4-wire WYE, w/ground
XN50-347/600-3GY 347/600VAC, 3 φ 4-wire WYE, w/ground
XN50-120/240-3GHD 120/240VAC, 3 φ high-leg DELTA, w/ground (B phase must be 208V)
XN50-240-3DG 240VAC, 3 φ, 3-wire DELTA, w/ground
XN50-380-3DG 380VAC, 3 φ, 3-wire DELTA, w/ground
XN50-480-3DG 480VAC, 3 φ, 3-wire DELTA, w/ground
XN50-600-3DG 600VAC, 3 φ, 3-wire DELTA, w/ground
TYPICAL CLAMPING VOLTAGE DATA (6kV / 500A Combination Waveform)
System Model Protection Modes
Voltage No. L-N L-G N-G L-L
120 / 240 XN50-120/240-2G 391 391 388 735
120 / 208 XN50-120/208-3GY 391 391 388 735
220 / 380 XN50-220/380-3GY 696 724 668 1340
277 / 480 XN50-277/480-3GY 890 868 82 1665
347 / 600 XN50-347/600-3GY 1152 1185 1040 2265
120 / 240 XN50-120/240-3GHD 391x696 391x724 388 735x1340
240 XN50-240-3DG – 724 – 735
380 XN50-380-3DG – 1185 – 1340
480 XN50-480-3DG – 1451 – 1717
600 XN50-600-3DG – 1663 – 2276
STANDARD TRANSEND 80 MODEL NUMBERS
Model No. System Voltage, Service Configuration
XN80-120/240-2G 120/240VAC, 1 φ 3-wire SPLIT-PHASE, w/ground
XN80-120/208-3GY 120/208VAC, 3 φ 4-wire WYE, w/ground
XN80-220/380-3GY 220/380VAC, 3 φ 4-wire WYE, w/ground
XN80-277/480-3GY 277/480VAC, 3 φ 4-wire WYE, w/ground
XN80-347/600-3GY 347/600VAC, 3 φ 4-wire WYE, w/ground
XN80-120/240-3GHD 120/240VAC, 3 φ high-leg DELTA, w/ground (B phase must be 208V)
XN80-240-3DG 240VAC, 3 φ 3-wire DELTA, w/ground
XN80-380-3DG 380VAC, 3 φ, 3-wire DELTA, w/ground
XN80-480-3DG 480VAC, 3 φ, 3-wire DELTA, w/ground
XN80-600-3DG 600VAC, 3 φ, 3-wire DELTA, w/ground
TYPICAL CLAMPING VOLTAGE DATA (6kV / 500A Combination Waveform)
System Model Protection Modes
Voltage No. L-N L-G N-G L-L
120 / 240 XN80-120/240-2G 391 391 388 735
120 / 208 XN80-120/208-3GY 391 391 388 735
220 / 380 XN80-220/380-3GY 696 724 668 1340
277 / 480 XN80-277/480-3GY 890 868 820 1665
347 / 600 XN80-347/600-3GY 1152 1185 1040 2265
120 / 240 XN80-120/240-3GHD 391x696 391x724 388 735x1340
240 XN80-240-3DG – 724 – 735
380 XN80-380-3DG – 1185 – 1340
480 XN80-480-3DG – 1451 – 1717
600 XN80-600-3DG – 1663 – 2276
STANDARD TRANSEND 100 MODEL NUMBERS |
|
|
|
Model No. |
System Voltage, Service Configuration |
XN100-120/240-2G |
120/240VAC, 1 φ 3-wire SPLIT-PHASE, w/ground |
|
|
XN100-120/208-3GY |
120/208VAC, 3 φ 4-wire WYE, w/ground |
|
|
XN100-220/380-3GY |
220/380VAC, 4 φ -wire WYE, w/ground |
|
|
XN100-277/480-3GY |
277/480VAC, 3 φ 4-wire WYE, w/ground |
|
|
XN100-347/600-3GY |
347/600VAC, 3 φ 4-wire WYE, w/ground |
|
|
XN100-120/240-3GHD |
120/240VAC, 3 φ high-leg DELTA, w/ground |
|
|
XN100-240-3DG |
240VAC, 3 φ 3-wire DELTA, w/ground |
|
|
XN100-380-3DG |
380VAC, 3 φ 3-wire DELTA, w/ground |
|
|
XN100-480-3DG |
480VAC, 3 φ 3-wire DELTA, w/ground |
|
|
XN100-600-3DG |
600VAC, 3 ,φ 3-wire DELTA, w/ground |
TYPICAL CLAMPING VOLTAGE DATA (6kV / 500A Combination Waveform) |
Protection Modes |
System Voltage |
Model No. |
L-N L-G N-G L-L |
120 / 240 |
XN100-120/240-2G |
391 391 388 735 |
120 / 208 |
XN100-120/208-3GY |
391 391 388 735 |
220 / 380 |
XN100-220/380-3GY |
696 724 668 1340 |
277 / 480 |
XN100-277/480-3GY |
890 868 820 1665 |
347 / 600 |
XN100-347/600-3GY |
1152 1185 1040 2265 |
120 / 240 |
XN100-120/240-3GHD |
391x696 391x724 388 735x1340 |
240 |
XN100-240-3DG |
– 724 – 735 |
380 |
XN100-380-3DG |
– 1185 – 1340 |
480 |
XN100-480-3DG |
– 1451 – 1717 |
600 |
XN100-600-3DG |
– 1663 – 2276 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|